Brand Name : SKYLINE
Model Number : SL-FL086
Certification : CE
Place of Origin : China
MOQ : 1 unit
Price : neogitable
Payment Terms : T/T, Western Union, MoneyGram
Supply Ability : 1 unit / month
Delivery Time : 20 working days
Packaging Details : plywood case
SKYLINE : Radiant Flooring Panel Apparatus
Standards : ISO 9239-1, ASTM E 648, ASTM E 970, NFPA 253
Dimension testing chamber : 2220(W)×1500(D)×2650(H)mm
Control chamber : 600(W)×600(D)×1600(H)mm
Gas control chamber : 600(W)×600(D)×1000(H)mm
Power : AC 220V, 50/60Hz, 25A
Weight : 220kg
Air supply option propane : 95%
Critical Radiant Flux is the main parameters of the fire risk for flooring materials, it reflects the burning and spreading ability of flooring material specimen under external heat radiation conditions. It is an important index of combustion classification for building products.
According to ISO9239-1,2 and GB/T 11785-2005 requirements, ISO 9239-1 Flooring Materials Radiant Analyzer with Good Price is measuring the critical radiant of combustion floor coverings, through the radiation environment of test chamber. It is can also be used to measure the critical radiation of the cellulose insulation floor material. Specimen is located at down horizon of 30 degree sloped gas radiation panel per horizon surface.
Dimension testing chamber | 2220(W)×1500(D)×2650(H)mm |
Control chamber | 600(W)×600(D)×1600(H)mm |
Gas control chamber | 600(W)×600(D)×1000(H)mm |
Power | AC 220V, 50/60Hz, 25A |
Weight | 220kg |
Air supply option propane | 95% |
Test Report
Report | |||
Testing agency | |||
Standard | |||
Operator | Test date | ||
Ambient temperature | Environment humidity | ||
Equipment deadline | |||
Product name | Sample serial number | ||
Model specification | |||
Sample size | Device Code | ||
Material density (g/㎡) | Test time(s) | ||
Debug balance | |||
Test Results: | |||
Distance (mm) | Flame front end time(s) | Distance(mm) | Flame front end time(s) |
60 | 560 | ||
110 | 610 | ||
160 | 660 | ||
210 | 710 | ||
260 | 760 | ||
310 | 810 | ||
360 | 860 | ||
410 | 910 | ||
460 | 960 | ||
510 | 1100 | ||
The front end of the flame reaches the longest distance (cm) | Critical radiant flux(kW/m2) | ||
Total smoke value(%.min) | Maximum absorption rate(%) | ||
10min flame front end reach distance(mm) | 10min critical radiant heat value(kW/m2) | ||
20min flame front end reach distance(mm) | 20min critical radiant heat value(kW/m2) | ||
30min flame front end reach distance(mm) | 30min critical radiant heat value(kW/m2) | ||
Ignition time(s) | Flame extinction time(s) | ||
The phenomenon observed during the test: |